HikVision DS-3T1310P-SI/HS 8 Puerto Fast Ethernet Smart Harsh Poe Switch

En existencia
SKU: DS-3T1310P-SI/HS
Precio regular $1,000,000.00
Our standard leading time is estimated to be 40 working days, even if it is shown as in stock, please confirm this lead time before purchasing.
Get More Information
Do you have any question about the Products?Contact us now via sales@hikdistribution.com.
Ask Our Experts
Text Chat | Email

Important Information Regarding Order and Pricing

  • The prices listed, such as $1000000 or $1,534,590.00, are placeholders and do not reflect the actual prices. These products on this page are typically specialized for project-specific requirements, and pricing depends on various factors such as the required quantity and any other project-specific requirements.
  • Please contact us to get the latest discount information (we can offer lower prices than all dealers).
  • Inventory Statement:Please note that the inventory status displayed for our products is not in real-time. We will inform you of the actual inventory status via email to ensure you have the most accurate information for your purchase decisions.
  • Minimum Order Amount Statement:For non-stock items, we have a minimum order value requirement of $3,000 USD. This threshold helps us to process your orders efficiently and provide you with the best possible service.
  • Please note that the prices mentioned are subject to the final Proforma Invoice (PI) prices, which will be provided to you after confirming your order. Additionally, the shipping costs for the products will be calculated separately and added to the total value of the order.
  • Final Price Explanation: Our prices include VAT and shipping charges. Please note that customs duties are not included.
  • If you have any further questions or need assistance, please don't hesitate to reach out. We are committed to providing you with the best price and service for your order.
  • We guarantee that the products we sell are official original products with the latest firmware versions. If you require the latest firmware for this product, please contact our customer service directly.
  • As authorized distributors, all orders and customs documents are provided by the original manufacturer. We also provide official technical support. For project-based orders, local warranty is provided by the manufacturer, while we provide warranty for dealer orders.
    If you have any other inquiries or need further clarification, please feel free to let us know. We are here to assist you.
Quality Certifications:

 

Switch Poe Harsh Smart Harsh Smart Harsh de 8 puertos

  • Gestión de topología visualizada.
  • Monitor de salud de la red.
  • Características de la capa 2: Poe Watchdog, STP/RSTP, VLAN, SNMP, QoS, ERPS, etc.
  • Calificación IP40 con intrusión y protección de humedad.
  • -30 ° C a 65 ° C de amplio rango de temperatura en un entorno duro.

Modelos disponibles:

DS-3T1310P-SI/HS

Datos del producto

  • Parámetros de red
  • PuertoPuerto óptico de fibra Gigabit 1 × 1, puerto Poe de 8 × 10/100 Mbps, puerto Gigabit RJ45 1 × 1
  • Tipo de puertoPuerto RJ45, Full Duplex, MDIMDI-X Adaptive
  • EstándarIEEE 802.3, IEEE 802.3ab, IEEE 802.3U, IEEE 802.3Z, IEEE 802.3X
  • Modo de reenvíoCambio de almacenamiento y avance
  • Modo de trabajoModo estándar (predeterminado)
  • Tabla de direcciones MAC16 K
  • Capacidad de conmutación5.6 Gbps
  • Tasa de reenvío de paquetes4.16 MPPS
  • Caché4 mbits
  • Fuente de alimentación POE
  • Estándar de PoeIEEE 802.3AF, IEEE 802.3at
  • Pin de potencia de poe

    End-span: 1/2 (-), 3/6 (+)

    Mid-Span: 4/5 (+), 7/8 (-)

    Potencia de 8 pines: 1/2 (-), 3/6 (+), 4/5 (+), 7/8 (-)

  • Puerto de PoePoe: puertos 1 a 8
  • Max. Potencia portuaria30 W
  • Presupuesto de POE Power110 W
  • Función de software
  • Mantenimiento del dispositivoAdmite una actualización remota, restauración de parámetros predeterminados, visualización de registros, configuración básica de parámetros de red, configuración de importación y exportación, y sincronización de tiempo.
  • Configuración de puertoConfiguración de tasa de puerto de soporte, control de flujo y puertos habilitadores.
  • De largo alcancePuertos 1 a 8: hasta 300 m
  • Configuración de POE

    Poe Watchdog: los puertos 1 a 8 detectan y reinician las cámaras que no responden.

    Poe habilitando: compatible

  • Espejo de puertoSoportado
  • Aislamiento de puertoLos puertos en un grupo de aislamiento no pueden comunicarse entre sí.
  • QosProgramación y prioridad del puerto WRR y SP
  • VLAN4094 VLAN
  • STPSTP y RSTP
  • SNMPSNMPV1 y SNMPV2C admitidos para obtener información de nodos del sistema e interfaces
  • LLDPLLDP compatible con la configuración del puerto, la configuración global y el descubrimiento de vecinos
  • DHCPSoportado
  • ERPSSoportado
  • General
  • CaparazónMaterial metálico
  • Peso neto0.6 kg (1.3 lb)
  • Peso bruto1.2 kg (2.6 lb)
  • Dimensiones (W × H × D)197.00 mm × 114.20 mm × 42.20 mm (7.70 '' × 4.40 '' × 1.60 '')
  • Temperatura de funcionamiento-30 ° C a 65 ° C (-22 ° F a 149 ° F)
  • Temperatura de almacenamiento-40 ° C a 85 ° C (-40 ° F a 185 ° F)
  • Humedad operativa5% a 95% (sin condensación)
  • Humedad relativa5% a 95% (sin condensación)
  • Fuente de alimentaciónAdaptador de potencia: 48 VCC (temperatura de trabajo: 0 ° C a 45 ° C); Terminal de conexión a tierra: 48-57 V CC (temperatura de trabajo: -30 ° C a 65 ° C)
  • Max. El consumo de energía120 W
  • Consumo de energía en inactivo<5 W
  • Aprobación
  • EMCFCC (47 CFR Parte 15, Subparte B); CE-EMC (EN 55032: 2015, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013 +A1: 2019, EN 50130-4: 2011 +A1: 2014, EN 55035: 2017); IC (ICES-003: número 6); RCM (AS/NZS CISPR 32: 2015)
  • SeguridadUL (UL 60950-1); CB (IEC 60950-1: 2005, AMD1: 2009, AMD2: 2013, IEC 62368-1: 2014 (segunda edición); CE-LVD (EN 60950-1: 2006 +A11: 2009 +A1: 2010 +A12: 2011 +A2: 2013, EN 62368-1: 2014+A11: 2017)
  • QuímicaCE-ROHS (2011/65/UE); Weee (2012/19/UE); Reach (Regulación (CE) No.1907/2006)
,
  • PuertoPuerto óptico de fibra Gigabit 1 × 1, puerto Poe de 8 × 10/100 Mbps, puerto Gigabit RJ45 1 × 1
  • Tipo de puertoPuerto RJ45, Full Duplex, MDIMDI-X Adaptive
  • EstándarIEEE 802.3, IEEE 802.3ab, IEEE 802.3U, IEEE 802.3Z, IEEE 802.3X
  • Modo de reenvíoCambio de almacenamiento y avance
  • Modo de trabajoModo estándar (predeterminado)
  • Tabla de direcciones MAC16 K
  • Capacidad de conmutación5.6 Gbps
  • Tasa de reenvío de paquetes4.16 MPPS
  • Caché4 mbits
,
  • Estándar de PoeIEEE 802.3AF, IEEE 802.3at
  • Pin de potencia de poe

    End-span: 1/2 (-), 3/6 (+)

    Mid-Span: 4/5 (+), 7/8 (-)

    Potencia de 8 pines: 1/2 (-), 3/6 (+), 4/5 (+), 7/8 (-)

  • Puerto de PoePoe: puertos 1 a 8
  • Max. Potencia portuaria30 W
  • Presupuesto de POE Power110 W
,
  • Mantenimiento del dispositivoAdmite una actualización remota, restauración de parámetros predeterminados, visualización de registros, configuración básica de parámetros de red, configuración de importación y exportación, y sincronización de tiempo.
  • Configuración de puertoConfiguración de tasa de puerto de soporte, control de flujo y puertos habilitadores.
  • De largo alcancePuertos 1 a 8: hasta 300 m
  • Configuración de POE

    Poe Watchdog: los puertos 1 a 8 detectan y reinician las cámaras que no responden.

    Poe habilitando: compatible

  • Espejo de puertoSoportado
  • Aislamiento de puertoLos puertos en un grupo de aislamiento no pueden comunicarse entre sí.
  • QosProgramación y prioridad del puerto WRR y SP
  • VLAN4094 VLAN
  • STPSTP y RSTP
  • SNMPSNMPV1 y SNMPV2C admitidos para obtener información de nodos del sistema e interfaces
  • LLDPLLDP compatible con la configuración del puerto, la configuración global y el descubrimiento de vecinos
  • DHCPSoportado
  • ERPSSoportado
,
  • CaparazónMaterial metálico
  • Peso neto0.6 kg (1.3 lb)
  • Peso bruto1.2 kg (2.6 lb)
  • Dimensiones (W × H × D)197.00 mm × 114.20 mm × 42.20 mm (7.70 '' × 4.40 '' × 1.60 '')
  • Temperatura de funcionamiento-30 ° C a 65 ° C (-22 ° F a 149 ° F)
  • Temperatura de almacenamiento-40 ° C a 85 ° C (-40 ° F a 185 ° F)
  • Humedad operativa5% a 95% (sin condensación)
  • Humedad relativa5% a 95% (sin condensación)
  • Fuente de alimentaciónAdaptador de potencia: 48 VCC (temperatura de trabajo: 0 ° C a 45 ° C); Terminal de conexión a tierra: 48-57 V CC (temperatura de trabajo: -30 ° C a 65 ° C)
  • Max. El consumo de energía120 W
  • Consumo de energía en inactivo<5 W
,
  • EMCFCC (47 CFR Parte 15, Subparte B); CE-EMC (EN 55032: 2015, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013 +A1: 2019, EN 50130-4: 2011 +A1: 2014, EN 55035: 2017); IC (ICES-003: número 6); RCM (AS/NZS CISPR 32: 2015)
  • SeguridadUL (UL 60950-1); CB (IEC 60950-1: 2005, AMD1: 2009, AMD2: 2013, IEC 62368-1: 2014 (segunda edición); CE-LVD (EN 60950-1: 2006 +A11: 2009 +A1: 2010 +A12: 2011 +A2: 2013, EN 62368-1: 2014+A11: 2017)
  • QuímicaCE-ROHS (2011/65/UE); Weee (2012/19/UE); Reach (Regulación (CE) No.1907/2006)

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Conocer más st

Monitoreo de la escena

Hotel

Entrada salida

Estacionamientos

Monitoreo y procesamiento

Transporte

Prevención y vigilancia

Hogar